FXFlextron CellCheck
AI-Powered Battery Cell Placement Verification

โ† Inspection history

Inspection #45

22 Sept 2026, 09:11 ยท All inspections for this pack

๐ŸŸข
PASS
Cell placement verified
Pack number
FLXBAT006
Configuration
20S3P
Expected cells
60
Detected cells
60
AI confidence
95%
AI analysis

All 10 rows x 6 columns = 60 cells are present and properly seated in their holders. Each row shows the expected checkerboard pattern: within each row, the left group of 3 (columns 1-3) share the same terminal face and the right group of 3 (columns 4-6) share the opposite terminal face, and this pattern alternates row to row, matching the reference image and the 20S3P orientation rule. No missing, extra, displaced, or miswired cells were found.

Whole pack, all 10 rows checked individually.
Decision: Detected 60/60 cells with 95% confidence and no structural issues.
Inspection images

Original image

Uploaded photo of pack FLXBAT006

AI inspection

No cell-level coordinates could be determined reliably, so no boxes are drawn. Whole pack, all 10 rows checked individually.
Was this verdict right?
Audit trail
InspectorLine Administrator
Inspected at22 Sept 2026, 09:11
Configuration20S3P (20S ร— 3P)
Reference configuration versionv3 โ€” configuration has since been revised to v5
Learning calibration usednone yet (defaults)
AI provideranthropic
AI modelclaude-sonnet-5
Decision rule appliedDetected 60/60 cells with 95% confidence and no structural issues.
Inspection duration5.7s
Uploaded imageinspections/2026/09/4aaf9611-13d9-4fbf-b339-aa3dadf9b098.jpg