FXFlextron CellCheck
AI-Powered Battery Cell Placement Verification

โ† Inspection history

Inspection #72

22 Sept 2026, 11:34 ยท All inspections for this pack

๐ŸŸก
REVIEW
Manual review required
Pack number
FLXBAT001
Configuration
20S3P
Expected cells
60
Detected cells
60
AI confidence
90%
AI analysis

Pack contains 60 cells arranged 10x6 as expected for 20S3P, and cell count is correct. However, two parallel groups show a reversed cell: row 8 column 3 and row 9 column 3 each show a teal-ringed positive face while the other two cells in their respective left-hand groups (columns 1-2) show flat negative discs. These should be corrected before the pack is accepted, as a mismatched cell within a parallel group can cause imbalance/short risk.

Decision: The AI model reported a possible orientation problem in 2 groups that could not be confirmed deterministically. Check row 8, column 3; row 9, column 3 by hand.
Cell orientation check
Could not verifyRead from insulator ring colour, independently of the AI model

The cell grid could not be located precisely enough in this photograph to verify orientation. Retake with the pack square to the camera and filling the frame.

C1C2C3C4C5C6R1BBBAAAR2AAABBBR3BBBAAAR4AAABBBR5BBBAAAR6AAABBBR7BBBAAAR8AAABBBR9BBBAAAR10AAABBA

A and B are the two ring colours. Every group of 3 must be one colour; adjacent groups alternate. marks a reversed cell.

Detected issues (4)
  • MEDIUMOrientation anomalyAI model suggestion, not confirmed by the ring-colour check: In row 8, columns 1-3 (left group), columns 1 and 2 show large flat silver discs (negative face, no ring) while column 3 shows a teal/green ring with a raised button (positive face). This cell is reversed relative to its two neighbours in the same parallel group.
  • MEDIUMOrientation anomalyAI model suggestion, not confirmed by the ring-colour check: In row 9, columns 1-3 (left group), columns 1 and 2 show large flat silver discs (negative face) while column 3 shows a teal ring with raised button (positive face), inconsistent with the rest of the group.
  • MEDIUMOrientation anomalyThe AI model reports that cells in row 8, columns 1-3 may not all face the same way (row 8, column 3). This could not be confirmed by the ring-colour check.
  • MEDIUMOrientation anomalyThe AI model reports that cells in row 9, columns 1-3 may not all face the same way (row 9, column 3). This could not be confirmed by the ring-colour check.
Inspection images

Original image

Uploaded photo of pack FLXBAT001

AI inspection

Annotated inspection of pack FLXBAT001
Was this verdict right?
Audit trail
InspectorLine Administrator
Inspected at22 Sept 2026, 11:34
Configuration20S3P (20S ร— 3P)
Reference configuration versionv5
Learning calibration usednone yet (defaults)
AI provideranthropic
AI modelclaude-sonnet-5
Decision rule appliedThe AI model reported a possible orientation problem in 2 groups that could not be confirmed deterministically. Check row 8, column 3; row 9, column 3 by hand.
Inspection duration24.0s
Uploaded imageinspections/2026/09/1ed9a7ce-69ec-4723-846b-30d2eff7ba9a.jpg
Record typeProduction