FXFlextron CellCheck
AI-Powered Battery Cell Placement Verification

โ† Inspection history

Inspection #73

22 Sept 2026, 11:36 ยท All inspections for this pack

๐ŸŸก
REVIEW
Manual review required
Pack number
FLXBAT002
Configuration
20S3P
Expected cells
60
Detected cells
60
AI confidence
90%
AI analysis

The pack contains 60 cells arranged in the expected 10x6 grid with 20 groups of 3, and the overall checkerboard orientation pattern between groups matches the expected series wiring. However, in row 8's left-hand group (columns 1-3), the third cell's terminal appearance (flatter, darker disc with a thinner yellow ring) differs from its two group-mates, suggesting it may be inserted backwards. Recommend operator visually re-check row 8, column 3 before proceeding.

Decision: The AI model reported a possible orientation problem in 1 group that could not be confirmed deterministically. Check row 8, column 3 by hand.
Cell orientation check
Could not verifyRead from insulator ring colour, independently of the AI model

The cell grid could not be located precisely enough in this photograph to verify orientation. Retake with the pack square to the camera and filling the frame.

C1C2C3C4C5C6R1BBBAAAR2AAABBBR3BBBAAAR4AAABBBR5BBBAAAR6AABBBBR7BBBAAAR8AAABBBR9BBBAAAR10AAABBA

A and B are the two ring colours. Every group of 3 must be one colour; adjacent groups alternate. marks a reversed cell.

Detected issues (2)
  • MEDIUMOrientation anomalyAI model suggestion, not confirmed by the ring-colour check: In row 8, columns 1-3, the third cell (column 3) shows a darker/greyish flat disc with a thin yellow ring, differing from the other two cells in that group which show large silver flat discs with thick yellow rings. Comparing terminal shape and ring proportion, this cell appears reversed relative to its two neighbours in the same parallel group.
  • MEDIUMOrientation anomalyThe AI model reports that cells in row 8, columns 1-3 may not all face the same way (row 8, column 3). This could not be confirmed by the ring-colour check.
Inspection images

Original image

Uploaded photo of pack FLXBAT002

AI inspection

Annotated inspection of pack FLXBAT002
Was this verdict right?
Audit trail
InspectorLine Administrator
Inspected at22 Sept 2026, 11:36
Configuration20S3P (20S ร— 3P)
Reference configuration versionv5
Learning calibration usednone yet (defaults)
AI provideranthropic
AI modelclaude-sonnet-5
Decision rule appliedThe AI model reported a possible orientation problem in 1 group that could not be confirmed deterministically. Check row 8, column 3 by hand.
Inspection duration22.5s
Uploaded imageinspections/2026/09/9533cb64-0769-416b-b051-208b2c435296.jpg
Record typeProduction