FLXBAT008

2 inspections recorded · latest 22 Sept 2026, 10:53

Latest result
20S3P · 60/60 cells · 92%
🔴 FAIL
22 Sept 2026, 10:53
20S3P · inspected by Line Administrator · ref v4 · claude-sonnet-5
🔴 FAIL
Inspection 57
Expected
60
Detected
60
Confidence
92%

All 60 holder positions are filled and the overall checkerboard alternation of yellow/green ring groups across rows matches the expected 20S3P pattern. However, in row 8 the left group of three cells (columns 1-3) is inconsistent: column 3 shows a flat disc without the green ring seen on columns 1 and 2, indicating that cell is inserted backwards relative to its own parallel group. This should be manually verified and the cell reoriented if confirmed.

Open full record →
22 Sept 2026, 10:44
20S3P · inspected by Line Administrator · ref v4 · claude-sonnet-5
🔴 FAIL
Inspection 55
Expected
60
Detected
60
Confidence
90%

The pack contains 60 cells arranged 10x6 as expected, and the overall row-to-row checkerboard alternation of ring colours (yellow vs green/teal) matches the expected series wiring pattern. However, within row 7's left-hand group (columns 1-3) and row 8's left-hand group (columns 1-3), one cell (column 3 in each case) shows a ring colour or terminal shape that does not match its two group-mates, indicating a cell inserted backwards. These two groups should be physically re-inspected and the odd cell reversed to match its neighbours before the pack is passed.