FXFlextron CellCheck
AI-Powered Battery Cell Placement Verification

โ† Inspection history

Inspection #75

22 Sept 2026, 11:41 ยท All inspections for this pack

๐ŸŸก
REVIEW
Manual review required
Pack number
FLXBAT004
Configuration
20S3P
Expected cells
60
Detected cells
60
AI confidence
85%
AI analysis

Pack contains 60 cells arranged in the expected 10x6 / 20 groups of 3 layout, matching the 20S3P count. However, in row 3's right-hand group (columns 4-6) the cell at column 4 does not show the same yellow insulator ring as its two group-mates at columns 5-6, indicating it is reversed relative to the rest of its parallel group. All other 19 groups show consistent terminal shape and ring colour across their three cells. Recommend operator visually re-check row 3, column 4 and correct the orientation if confirmed.

Decision: The AI model reported a possible orientation problem in 1 group that could not be confirmed deterministically. Check row 3, column 4 by hand.
Cell orientation check
Not readable on this packRead from insulator ring colour, independently of the AI model

No colour-coded insulator rings were detected, so cell orientation could not be read from the photograph.

A and B are the two ring colours. Every group of 3 must be one colour; adjacent groups alternate. marks a reversed cell.

Detected issues (2)
  • MEDIUMOrientation anomalyAI model suggestion, not confirmed by the ring-colour check: In row 3, columns 4-6 group, the cell at column 4 shows a large flat plain disc without a visible yellow insulator ring, while its two neighbours at columns 5-6 show large flat discs with a yellow ring visible around the edge. This indicates the column 4 cell is facing the opposite way to the rest of its own parallel group.
  • MEDIUMOrientation anomalyThe AI model reports that cells in row 3, columns 4-6 may not all face the same way (row 3, column 4). This could not be confirmed by the ring-colour check.
Inspection images

Original image

Uploaded photo of pack FLXBAT004

AI inspection

Annotated inspection of pack FLXBAT004
Was this verdict right?
Audit trail
InspectorLine Administrator
Inspected at22 Sept 2026, 11:41
Configuration20S3P (20S ร— 3P)
Reference configuration versionv5
Learning calibration usednone yet (defaults)
AI provideranthropic
AI modelclaude-sonnet-5
Decision rule appliedThe AI model reported a possible orientation problem in 1 group that could not be confirmed deterministically. Check row 3, column 4 by hand.
Inspection duration24.0s
Uploaded imageinspections/2026/09/9d3cc442-619e-4050-aa33-cb8940836f76.jpg
Record typeProduction