FXFlextron CellCheck
AI-Powered Battery Cell Placement Verification

← Inspection history

FLXBAT004

2 inspections recorded · latest 22 Sept 2026, 11:41

Latest result
20S3P · 60/60 cells · 85%
🟡 REVIEW
22 Sept 2026, 11:41
20S3P · inspected by Line Administrator · ref v5 · claude-sonnet-5
🟡 REVIEW
Inspection 75
Expected
60
Detected
60
Confidence
85%

Pack contains 60 cells arranged in the expected 10x6 / 20 groups of 3 layout, matching the 20S3P count. However, in row 3's right-hand group (columns 4-6) the cell at column 4 does not show the same yellow insulator ring as its two group-mates at columns 5-6, indicating it is reversed relative to the rest of its parallel group. All other 19 groups show consistent terminal shape and ring colour across their three cells. Recommend operator visually re-check row 3, column 4 and correct the orientation if confirmed.

Open full record →
22 Sept 2026, 09:09
20S3P · inspected by Line Administrator · ref v3 · claude-sonnet-5
🟢 PASS
Inspection 43
Expected
60
Detected
60
Confidence
96%

All 10 rows x 6 columns are populated with 60 cells total, matching 20S3P. Each row shows a checkerboard pattern: left group (columns 1-3) and right group (columns 4-6) face opposite ways, and the pattern flips between rows as expected for series wiring. Within every group of 3, all cells face the same direction (either all flat plain discs or all button-in-ring), so no orientation anomaly is present.

Open full record →